Product Details
Attribute | Details |
---|
Conductor | Solid bare copper |
Insulation | 18-16AWG, 14-12AWG |
Jacket | Low smoke PVC |
Shield | Aluminum Mylar |
Voltage Rating | 300V |
Temperature Rating | -5℃ to 75℃ |
Drain Wire | 24 AWG |
Common Product Specifications
Specification | Details |
---|
Jackets | PVC, LSZH, PE |
Color | Red |
Usage | Wiring burglar & security alarms |
Industrial Use | Fire security cable |
Origin | Hangzhou Zhejiang |
Product Manufacturing Process
According to authoritative industry sources, the manufacturing of shielded fire alarm cables involves several precise steps to ensure quality and reliability. The process begins with the selection of high-quality copper for conductors, which is then insulated with flame-retardant materials such as PVC or LSZH. This is followed by the application of shielding, typically using aluminum Mylar, to prevent electromagnetic interference. The final step is the extrusion of the outer jacket, providing mechanical durability and fire resistance. Regular testing at each stage ensures compliance with safety and performance standards.
Product Application Scenarios
Shielded fire alarm cables are essential in environments prone to electromagnetic interference (EMI) and radio-frequency interference (RFI). They are widely used in commercial buildings like shopping malls and offices, where electronic devices abound. In industrial settings, they ensure dependable alarm system operation amidst heavy machinery. Residential applications include high-rise buildings where interference from numerous electronic devices is expected. The importance of these cables is underscored in ensuring signal integrity and reliability, critical for timely fire alerts and occupant safety.
Product After-Sales Service
Our commitment to customer satisfaction extends beyond purchase. We offer comprehensive after-sales support for our shielded fire alarm cables, including technical assistance, installation advice, and prompt warranty services. Our dedicated support team is ready to address any concerns or challenges you may encounter, ensuring a seamless experience with our products.
Product Transportation
Ensuring the safe and timely delivery of our shielded fire alarm cables is paramount. We partner with reputable logistics providers to offer reliable shipping solutions. Our cables are packaged in robust, export-grade materials to protect them from damage during transit. Standard lead times apply, and we offer timely updates to keep our clients informed about their shipment status.
Product Advantages
- High Interference Resistance: Shielded design for clear signal transmission.
- Durable Construction: Made with quality materials for long-lasting performance.
- Fire Safety: Compliant with fire safety standards ensuring minimal toxic emissions.
Product FAQ
- What is the main advantage of using a shielded fire alarm cable?—The primary advantage of using shielded fire alarm cables is their ability to prevent electromagnetic interference from distorting the critical signals needed for fire alarms, ensuring timely alerts.
- Is this cable suitable for outdoor use?—While primarily designed for indoor applications, shielded fire alarm cables can be used outdoors if properly shielded from environmental conditions.
- Can this cable be used with other security systems?—Yes, in addition to fire alarms, these cables are suitable for burglar alarms and other low voltage security systems.
- What certifications do these cables have?—Our cables come with CE, RoHS, IEC, and ISO9001 certifications, evidencing their quality and conformity with international standards.
- How should I install the cable to maximize its performance?—For optimal performance, ensure the cable layout minimizes bends and is secured away from high-voltage lines that could introduce interference.
- What safety measures are in place for these cables?—The cables are constructed with flame-retardant materials and low smoke emission properties, suitable for maintaining safety during fire events.
- How do I troubleshoot if the alarm system is not working?—Ensure all connections are secure, check for physical damages, and verify that the cable is correctly interfaced with the alarm system.
- Is customization available for specific installation needs?—Yes, we offer customization options for large orders to meet specific installation requirements, subject to terms and conditions.
- What maintenance does the cable require post-installation?—Regular inspections for physical integrity and consistent performance testing of the alarm systems are recommended to ensure longevity.
- What is the lifespan of these cables?—With proper installation and maintenance, our shielded fire alarm cables can last for several decades.
Product Hot Topics
- Why choose shielded fire alarm cables for your building?—Shielded fire alarm cables provide unparalleled reliability in environments susceptible to electrical interference. They are manufactured to uphold strict safety standards, ensuring effectiveness during critical moments. Investing in these cables is an investment in the safety and security of a building's occupants, reaffirming their importance in modern construction and renovation projects.
- Comparing shielded fire alarm cables with unshielded alternatives—When deciding between shielded and unshielded fire alarm cables, the choice primarily revolves around location and interference levels. Shielded cables excel in environments bombarded with EMI and RFI, ensuring that crucial alarm signals are not compromised. Unshielded alternatives may suffice in quieter environments but lack the protection needed in complex electrical landscapes.
Image Description